Enterprise Instrumentation: The 'sessionName' parameter of value 'TraceSession' is not valid

We are still using Enterprise Instrumentation(that was created during .Net 1.1 time)
In new Server 2008 environment and IIS 7 we have the following errors:
The 'sessionName' parameter of value 'TraceSession' is not valid. A trace session of this name does not exist in the TraceSessions configuration file for Windows Trace Session Manager service. Ensure that a session of this name exists in the TraceSessions configuration file and that the Windows Trace Session Manager service is started.
   at Microsoft.EnterpriseInstrumentation.EventSinks.TraceEventSink..ctor(IDictionary parameters, EventSource eventSource)
   --- End of inner exception stack trace ---
   at System.RuntimeMethodHandle._InvokeConstructor(IRuntimeMethodInfo method, Object[] args, SignatureStruct& signature, RuntimeType declaringType)
   at System.Reflection.RuntimeConstructorInfo.Invoke(BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture)
   at System.RuntimeType.CreateInstanceImpl(BindingFlags bindingAttr, Binder binder, Object[] args, CultureInfo culture, Object[] activationAttributes)
   at Microsoft.EnterpriseInstrumentation.EventSinks.EventSink.CreateNewEventSinks(DataRow[] eventSinkRows, EventSource eventSource)

I’ve seen the same errors on development Win7 machines when using IIS. It seems not a problem on Cassini.

I've checked ,that Windows Trace Session Manager Service has started and 
The file C:\Program Files (x86)\Microsoft Enterprise Instrumentation\Bin\Trace Service\TraceSessions.config has corresponding entry
<?xml version="1.0" encoding="utf-8" ?>
<configuration xmlns="http://www.microsoft.com/schema/EnterpriseInstrumentation/v1/TraceSessions.xsd">
                <defaultParameters minBuffers="4" maxFileSize="10" maxBuffers="25" bufferSize="20" logFileMode="sequential" flushTimer="3" />
                <sessionList>
                                 <session name="TraceSession" enabled="false" fileName="C:\Program Files (x86)\Microsoft Enterprise Instrumentation\Bin\Trace Service\Logs\TraceLog.log" />
                </sessionList>
</configuration>
The errors still continue, but I was able to disable  the parameter in  eventSink configuration

   <eventSink name=" traceSink" description=" Outputs events to the Windows Event Trace." type ="Microsoft.EnterpriseInstrumentation.EventSinks.TraceEventSink ">
                <!-- MNF disabled parameter to  avoid error "The 'sessionName' parameter of value 'TraceSession' is not valid" 
                     < parameter name ="sessionName " value ="TraceSession " />
                    -->
    </ eventSink>


One day I wish to replace all EnterpriseInstrumentation calls with NLog.